Classification |
Category |
Tolerance Limit |
Drinking
Water Source without conventional treatment but after disinfections |
A |
- Total Coliform Organism MPN/100 ml shall be 50 or less
- pH between 6.5 and 8.5
- Dissolved Oxygen 6mg/l or
more
- Biochemical oxygen demand 5
days 20o C 2mg/l or less
|
Outdoor
Bathing (Organized
) |
B |
- Total Coliforms Organism MPN/100 ml shall be 500 or less
- pH between 6.5 and 8.5
- Dissolved Oxygen 5mg/l or
more
- Biochemical Oxygen Demand 5
days 20oC 3mg/l or less
|
Drinking
Water source after conventional treatment and disinfections
|
C |
- Total Coliforms Organism MPN/100 ml shall be 5000 or less
- pH between 6.5 and 8.5
- Dissolved Oxygen 4mg/l or
more
- Biochemical Oxygen Demand 5
days 20oC 3mg/l or less
|
Propagation
of Wild Life and Fisheries |
D |
- pH between 6.5 and 8.5
- Dissolved Oxygen 4mg/l or
more
- Free Ammonia ( as N )1.2
mg/l or less
|
Irrigation
Industrial Cooling, Controlled waste disposal
|
E |
- pH between 6.0 and 8.5
- Electrical Conductivity at
25oC micro mhos/cm Max. 2250
- Sodium absorption ratio
Max. 26
- Boron Max. 2 mg/l
|